MET Fumarate
$42.00
MET Fumarate, specified at ≥99% HPLC purity where supported by a batch CoA, for authorised analytical and laboratory research in the USA and Europe. Request the current CoA and SDS from Roid Chem Store .com before procurement.
Prices are per gram
Buy MET Fumarate for Advanced Laboratory Research in the USA and Europe
MET Fumarate is an analytical research material commonly described as N-ethyl-N-methyltryptamine fumarate. Because “MET” is also used for structurally different compounds, including 4-AcO-MET and 5-fluoro-MET, laboratories must verify the exact molecular identity, salt stoichiometry, CAS number and batch documentation before procurement. Roid Chem Store .com may present this material for authorised laboratory research in the USA and Europe, subject to applicable regulations and documented product specifications.
Uncompromising Purity and Analytical Characterisation
The product specification should state ≥99.0% purity by HPLC only when that result is supported by the current batch-specific certificate of analysis. A “≥99%” claim without an accompanying CoA is insufficient for high-integrity laboratory procurement. The CoA should identify the compound, salt form, batch number, test date, analytical method, acceptance criteria and reported result.
For MET Fumarate, identity confirmation should use orthogonal techniques where practical. HPLC or LC-UV can establish chromatographic purity, while LC-MS or high-resolution mass spectrometry can support molecular-mass confirmation. NMR may provide additional confirmation of the indole structure, amine substituents and fumarate component. These techniques should be interpreted alongside the documented molecular formula and salt stoichiometry rather than used in isolation.
Residual solvents should be assessed by a validated GC method and reported individually on the CoA. The report should identify detected solvents, reporting limits and applicable acceptance criteria. Where required by the laboratory’s quality system, elemental impurities should be examined using ICP-MS or ICP-OES. Numerical limits for lead, arsenic, mercury, cadmium and other elements should not be invented or described as “compliant” unless the batch has been tested against a defined specification.
The physical description should remain evidence-based. MET Fumarate is expected to be supplied as a solid material, but the exact colour, particle morphology, hydration state and degree of crystallinity can vary between batches. The final listing should therefore state the observed appearance recorded on the CoA, such as “solid; colour and morphology confirmed by batch documentation”, rather than guaranteeing a particular crystalline form without supporting data.
High purity is important for reproducible analytical research. Trace related substances can alter retention time, ionisation efficiency, mass-spectral response, reaction performance and matrix effects. In contrast, lower-grade technical reagents may contain unidentified impurities that interfere with calibration, method validation or interpretation of in-vitro data. Purity alone does not establish suitability: laboratories must also consider identity, assay basis, water content, residual solvents, stability and chain of custody.
The product must not be confused with 4-AcO-MET Fumarate. Public reference-standard listings identify 4-AcO-MET Fumarate as a separate compound with a different molecular formula and CAS number. Procurement teams should compare the complete chemical name, structure, formula and CAS number—not merely the abbreviation “MET”.pubchem.ncbi.nlm.nih+1
Principal Laboratory Applications and Research Methodologies
MET Fumarate may be considered for controlled laboratory research after the material has been positively identified and its regulatory status reviewed. Potential applications include:
-
Analytical method development. A characterised batch may support LC-MS, LC-MS/MS or HPLC method development, including evaluation of retention behaviour, detector response, matrix effects, extraction recovery and system suitability.
-
Analytical reference-material work. Qualified laboratories may use the material to prepare research solutions or assess instrument response. It should not be called a certified reference material unless it has been certified under an appropriate reference-material scheme.
-
Forensic and analytical chemistry. The compound may be relevant to mass-spectral library development, confirmatory-method research and laboratory proficiency exercises where permitted. Reference-standard suppliers distinguish structurally related MET analogues by individual chemical identity, demonstrating why exact compound confirmation is essential.lgcstandards+1
-
Chemical synthesis and reaction monitoring. Where authorised, the material may be evaluated as a synthetic substrate, analytical comparator or reaction-monitoring compound. Any procedure should use the confirmed molecular structure and documented molecular weight rather than relying on the abbreviated product name.
All applications are restricted to laboratory research, analytical development and other authorised scientific investigation. Work must be performed by qualified personnel within an appropriate institutional framework, such as a university, contract research organisation, forensic laboratory, pharmaceutical R&D facility or analytical testing laboratory.
USA and European laboratories should independently review federal, national, state or regional requirements before procurement. Availability in one jurisdiction does not establish legality in another, and shipping eligibility may depend on destination, customs classification, institutional authorisation and carrier policy.
Compound Stability, Optimal Storage, and Safe Handling Protocols
The stability of MET Fumarate should be confirmed using supplier data and, where necessary, an internal stability assessment. The material should be protected from direct light, humidity, heat and avoidable exposure to air. The fumarate form may assist with solid-state handling, but it does not eliminate the need for moisture and temperature control.
Unless the supplier specifies otherwise, laboratories may consider the following provisional storage approach:
-
Short-term storage: keep the sealed container at approximately 2–8°C, protected from light and moisture.
-
Long-term storage: use a validated −20°C condition, with the material sealed in moisture-resistant primary packaging.
-
Opening procedure: allow a refrigerated container to equilibrate while closed before opening, reducing the risk of condensation.
-
Stock management: use suitable aliquots where repeated opening could expose the material to humidity or temperature cycling.
-
Excursion control: document storage deviations, appearance changes and any investigation or retesting.
These are general laboratory controls and do not replace the supplier’s SDS or validated stability data. EU downstream-user obligations and hazard communication depend on the substance’s classification and supply circumstances.echa.europa+1
Handling should take place in a certified fume cupboard or other approved containment system. Personnel should wear a laboratory coat, suitable nitrile gloves and chemical splash goggles. Avoid dust generation, aerosol formation, skin or eye contact and contamination of work surfaces. Use dedicated tools and collect waste in a labelled container for disposal through the institution’s approved chemical-waste service.
Solubility and stock-solution concentration should not be guaranteed without validated data. Laboratories should conduct a small-scale compatibility assessment in the selected solvent, documenting concentration, solvent grade, filtration, container material and storage duration. The behaviour of the fumarate salt may differ from that of the corresponding free base or another salt form.
Technical Specifications and Molecular Attributes
The following table refers to the presumed unsubstituted MET fumarate. The supplier should confirm all entries against the current batch CoA and SDS before publication.
| Attribute | Specification |
|---|---|
| Product name | MET Fumarate |
| Chemical identity | N-ethyl-N-methyltryptamine fumarate |
| IUPAC name | 2-(1H-indol-3-yl)-N-ethyl-N-methylethan-1-amine fumarate, subject to salt-form confirmation |
| CAS Registry Number | Must be confirmed by the supplier; public listings are inconsistent |
| Molecular formula | Commonly represented as C₁₃H₁₈N₂ · C₄H₄O₄ for a 1:1 fumarate salt |
| Approximate formula mass | Approximately 318.4 g/mol for the 1:1 representation |
| Exact mass | Must be calculated from the confirmed molecular formula and protonation state |
| Physical state and colour | Solid; exact appearance to be recorded on the batch CoA |
| Solubility profile | Requires batch-specific laboratory verification in the selected solvent |
| Typical purity | ≥99.0% by HPLC only when supported by the current batch CoA |
| Identity testing | Preferably LC-MS or HRMS with orthogonal NMR confirmation |
| Residual solvents | Validated GC analysis with individual results reported |
| Elemental impurities | Reported where required by the laboratory specification |
| Long-term storage | Sealed, dry, light-protected storage, typically −20°C where validated |
The identity must be checked particularly carefully because 4-AcO-MET Fumarate is a different substance with formula C₁₉H₂₄N₂O₆, while 5-fluoro-MET fumarate is also separately identified in analytical-reference catalogues.pubchem.ncbi.nlm.nih+1
Roid Chem Store .com: Your Premier USA and European Vendor for High-Purity Reagents
Roid Chem Store .com can position MET Fumarate as a laboratory-research material for eligible USA and European customers where the supplier can provide accurate product documentation. The procurement file should include the current batch CoA, SDS, product identifier, salt form, storage information, packaging details and any applicable shipping restrictions.
A ≥99% purity claim should be linked to the relevant batch documentation. The page should also allow laboratory managers to request information about HPLC conditions, identity testing, assay basis, residual solvents, elemental impurities, retest date and packaging integrity.
An ISO 9001 claim should be published only if a valid certificate is available for the correct legal entity and scope. ISO 9001 concerns a quality-management system; it does not independently certify the purity of MET Fumarate. Likewise, statements about temperature-controlled shipping, discreet packaging or delivery throughout all USA and European destinations should be limited to services that the supplier can document.iso
For USA and European procurement, fulfilment remains subject to destination-specific laws, customs processes, carrier acceptance and institutional purchasing controls. Customers should complete their own regulatory review before ordering, importing, storing or using the material.
You must be logged in to post a review.

Reviews
There are no reviews yet.