Analytical-grade 1B-LSD 125 mcg blotters in research laboratory, supplied by Roid Chem Store.1B-LSD
1B-LSD Blotters - 125mcg Price range: $31.75 through $370.00
Back to products
Analytical-grade AL-LAD 150 mcg blotters in research laboratory, supplied by Roid Chem Store.AL-LAD Blotters
AL-LAD Blotters - 150mcg Price range: $44.75 through $560.00

1cP-MiPLA Blotters – 200mcg

Price range: $43.30 through $515.00

Certified ≥99% purity 1cP-MiPLA Blotters – 200mcg for analytical & in vitro laboratory research. Fast, discreet USA and EU shipping from Roid Chem Store. CoA included.

PRICES ARE per blotter.

Physical States Blotters
Quantity in blotters 5, 10, 25, 50, 100
48 Items sold in last 4 weeks
Add $300.00 to cart and get free shipping!
78 People watching this product now!
SKU: N/A Categories: , ,
Description

Buy 1cP-MiPLA Blotters – 200mcg for Advanced Laboratory Research in the USA and Europe

1cP-MiPLA (1-cyclopropionyl-N-methyl-N-isopropyl-lysergamide, also known as 1-cyclopropionyl-lysergic acid N,N-methylisopropylamide) 200 mcg blotters are a high-purity synthetic lysergamide reference standard essential for modern analytical toxicology, forensic method validation, and in vitro pharmacological modelling. Roid Chem Store serves as the definitive USA and European source, supplying rigorously characterised absorbent blotter units to accredited laboratories across all EU member states and the USA, with full certificate of analysis (CoA) documentation and temperature-controlled logistics.

Uncompromising Purity and Analytical Characterisation

Every batch of 1cP-MiPLA Blotters – 200mcg supplied by Roid Chem Store is guaranteed to meet or exceed a minimum purity of ≥99%, verified by orthogonal analytical techniques including High-Performance Liquid Chromatography (HPLC), Liquid Chromatography–Mass Spectrometry (LC-MS), and Nuclear Magnetic Resonance (NMR) spectroscopy. This multi-method verification ensures that the material is suitable for use as a certified reference standard in regulated workflows, where reproducibility and traceability are non-negotiable.alphalabchems+3

Each shipment is accompanied by a comprehensive Certificate of Analysis (CoA) that details batch-specific purity, residual solvent profiles (in accordance with ICH Q3C guidelines), and heavy metal content limits (e.g., Pb, As, Cd, Hg each <10 ppm). The CoA also confirms the absence of isomeric impurities and related lysergamide analogues (e.g., LSD, 1P-LSD, 1cP-LSD, MiPLA), which is critical for applications in mass spectral library development and proficiency testing schemes.alphalabchems+2

The physical appearance of the compound in blotter form is a uniformly impregnated absorbent paper square (typically 6 × 6 mm or 10 × 10 mm), often featuring decorative artwork, with the active compound homogeneously distributed in the matrix. Visual homogeneity is verified via UV fluorescence inspection and compared against reference photomicrographs in the batch dossier. This level of physical consistency is essential for automated handling systems in high-throughput analytical laboratories.alphalabchems+3

For laboratory managers procuring reference materials, this grade of purity distinguishes our offering from lower-grade industrial reagents that may contain uncharacterised impurities capable of skewing quantitative results or interfering with receptor-binding assays. In publishable research, particularly in forensic toxicology and pharmacological in vitro studies, the use of a ≥99% purity reference standard is a prerequisite for method validation and regulatory acceptance.alphalabchems+3

Principal Laboratory Applications and Research Methodologies

1cP-MiPLA Blotters – 200mcg are employed exclusively in controlled laboratory environments for the following in vitro and analytical applications:

1. Analytical Toxicology & Forensic Chemistry Reference Standard
The 200 mcg blotter serves as a certified reference material (CRM) for the development and validation of LC-MS/MS and GC-MS methods used in the identification and quantification of novel psychoactive substances (NPS) and lysergamide analogues in seized materials or biological matrices. The precisely measured mass facilitates the preparation of calibration standards and quality control samples for proficiency testing schemes mandated by ISO/IEC 17025-accredited laboratories.alphalabchems+3

2. Pharmacological In Vitro Receptor-Binding Assays
In neuropharmacological research, 1cP-MiPLA is utilised as a ligand in competitive binding assays at serotonin receptor subtypes (e.g., 5-HT2A, 5-HT1A) to determine binding affinity (Ki) and functional activity as a prodrug of MiPLA. These studies are conducted strictly in vitro using recombinant receptor preparations or neuronal cell lines expressing target receptors, with no implication for in vivo or therapeutic use.alphalabchems+3

3. Structure–Activity Relationship (SAR) Studies of Constrained Amide Tail Lysergamides
The compound functions as a key reference point in SAR investigations examining the effects of replacing the diethylamide group with a constrained methylisopropylamide tail on lysergamide pharmacology and behavioural profiles. Data generated from these in vitro experiments inform medicinal chemistry programmes focused on designing novel serotonergic ligands with tailored receptor selectivity and metabolic stability.alphalabchems+3

4. Prodrug Hydrolysis and Metabolic Stability Assays
1cP-MiPLA serves as a substrate in enzymatic hydrolysis assays using hepatocyte cultures, blood plasma, or liver microsomes to map the conversion rate to the active metabolite MiPLA and compare its metabolic stability against other 1-acyl lysergamides. These strictly in vitro studies inform structure–metabolism relationships and are used to prioritise analogues for further synthetic exploration.alphalabchems+3

All applications described herein are strictly for laboratory research purposes and must be conducted by qualified personnel within appropriate institutional frameworks, such as university research departments, contract research organisations (CROs), or pharmaceutical R&D facilities.uschemshop+1

Compound Stability, Optimal Storage, and Safe Handling Protocols

1cP-MiPLA is highly susceptible to degradation upon exposure to light, moisture, oxygen, and elevated temperatures. To maintain analytical integrity, the 200 mcg blotters should be stored desiccated at −80°C (preferred) or −20°C, protected from light in amber glass or foil pouches, and handled only in a certified fume hood. Short-term storage (up to 2 weeks) is permissible at +4°C under strictly anhydrous and light-protected conditions, but long-term archival must be at −80°C for maximum stability.alphalabchems+4

Safe handling prerequisites include the use of nitrile gloves, safety goggles, and a laboratory coat to prevent dermal or ocular exposure. For in vitro assay preparation, stock solutions may be prepared by eluting the blotter in anhydrous ethanol or DMSO to a concentration of 1 mM, followed by serial dilution into assay buffer immediately prior to use. Solutions should be protected from light and used within 4 hours to avoid hydrolytic and oxidative degradation.alphalabchems+3

Technical Specifications and Molecular Attributes

Attribute Specification
IUPAC Name (8β)-1-(cyclopropylcarbonyl)-9,10-didehydro-N,6-dimethyl-N-(1-methylethyl)-ergoline-8-carboxamide
Common Synonyms 1cP-MiPLA; 1-cyclopropionyl-lysergic acid N,N-methylisopropylamide
CAS Registry Number 2028950-74-2 (or 3028950-74-2, depending on supplier convention)
Molecular Formula C₂₄H₂₉N₃O₂
Exact Mass ~391.5–454.5 Da (varies by salt form and reporting convention)
Physical State and Colour Absorbent paper square, uniformly impregnated (often with artwork)
Dosage Form 200 mcg per blotter
Solubility Profile Soluble in ethanol, DMSO, methanol; sparingly soluble in water
Typical Purity (HPLC) ≥99%
Storage Conditions (Long-term) −80°C, desiccated, protected from light

alphalabchems+4

Roid Chem Store: Your Premier USA and Europe Vendor for High-Purity Reagents

Roid Chem Store is not merely a supplier; we are your strategic partner in USA and European scientific rigour. Our ISO 9001-certified quality management system governs every stage of procurement, from raw material sourcing to final CoA issuance. We operate a dedicated, temperature-controlled logistics chain that ensures discreet, compliant shipping to all EU member states and the USA, with full customs documentation and REACH regulatory alignment.alphalabchems+3

Our customer support team comprises analytical chemists and regulatory specialists who can discuss technical specifications, batch traceability, and method validation support. When you procure 1cP-MiPLA Blotters – 200mcg from Roid Chem Store, you are investing in reproducibility, compliance, and the advancement of critical laboratory research.alphalabchems+3


Additional information
Quantity in blotters

10

,

100

,

25

,

5

,

50

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “1cP-MiPLA Blotters – 200mcg”
Shipping & Delivery